Operation of Shandong Hesper Hydro Cyclone

2023-08-09 05:49:13

Hydro Cyclone is one kind of Shandong Hesper’s main products, we can make single cyclones, also can design and customize hydro cyclone groups according to customers requests. Do you know how the cyclone work? The operation of hydro cyclone requires professional personnel, so as to ensure the normal operation of the cyclone in the later stage.

1. Before starting the testing hydro cyclone, make sure that all the connection points of hydro cyclone unit are fastened, and remove all kinds of residues in the pipelines and the unit box, to avoid leakage and blockage after starting testing. Make sure to fully open the valves of cyclones which are put into operation.

2. The valves can be fully opened (when starting the hydro cyclone group) or completely closed (when standby the hydro cyclone group), but it is not allowed to be in a half-open state (that is, it is not allowed to use the valve to control the flow).

3. If condition permits, please test the cyclone with clean water in advance. The feed to the cyclone can be provided by pump or head tank. If the pump matches the cyclone throughput, the pressure gauge shows a constant reading, to ensure that the pressure gauge readings do not fluctuate. If there are significant fluctuations, need to find out the reason. The equipment is required to work under a pressure but not higher than 0.3MPa.

4. When the hydro cyclone is running smoothly under normal pressure, check the leakage at the connection point and take remedial measures if necessary.

5. Check for blockage which caused by residue entering the cyclone. The clogging of the feed port of the cyclone will reduce the flow of overflow and grit, and the clogging of the grit port of the cyclone will reduce the flow of grit or even stop it, and sometimes violent vibration will occur. In case of blockage, the cyclone feeding valve should be closed in time to remove the blockage. In order to prevent clogging, facilities to prevent coarse materials and sundries (such as chip removal screen) can be added to the feeding tank of the hydrocyclone group. At the same time, the feeding tank should be emptied in time when parking to avoid sedimentation, Concentration is too high and cause blockage accidents.

6. When the hydro cyclone is proved to be in good condition by the clean water test, the slurry can be input for operation.

If you are interested in hydro cyclone or in need, welcome to CONTACT US.